Look, nobody wants to memorize that register 40001 is the temperature sensor. Life is too short and Modbus addresses are too many. This is an MCP Server for Modbus TCP devices -- you define device profiles in YAML, and then AI agents can read/write PLC registers by name like civilized beings.
It also ships with a built-in simulator, because we all know you don't have a PLC sitting on your desk. (And if you do, please dust it off.)
I kept looking at existing MCP servers for Modbus and kept finding the same four disappointments:
- No semantic register mapping -- the AI has to know raw addresses like
40001. Asking it to "read temperature" gets you a blank stare. - No data type conversion -- everything comes back as raw uint16, because apparently float32 is too fancy.
- No built-in simulator -- want to test? Go buy hardware. Or beg a colleague. Or stare at the ceiling.
- No device profiles -- no way to pre-configure connection details and register maps, so you get to type the same host/port/slave_id over and over like it's 1998.
So I did the unreasonable thing and fixed all four myself.
User (CLI / Chat / OpenClaw)
→ AI Agent (Claude / OpenClaw / etc.)
→ MCP Protocol (Streamable HTTP)
→ kc_modbus_mcp (FastMCP Server)
→ Profile Manager (YAML device profiles)
→ pymodbus (async Modbus TCP client)
→ Modbus TCP Device / Built-in Simulator
- Natural language control -- "read the factory temperature" just works. No address lookup tables taped to your monitor.
- YAML device profiles -- map register names to addresses, data types, units, and scaling. Finally, configuration that reads like English.
- 8 MCP tools -- 5 profile-based + 3 raw mode for when you need to go full hacker.
- Auto data type conversion -- float32, int32, uint16, bool -- with byte order and scale support, because doing bit math in your head at 2 AM is not a personality trait.
- Built-in Modbus TCP simulator -- sine-wave temperature, random humidity/pressure, writable coils. Your imaginary factory is doing great.
- Docker-ready --
docker compose up -dand you're in business. Two containers, zero excuses. - OpenClaw skill -- wrapper script for local LLM agents who prefer the command line lifestyle.
Security Notice: This is a POC/development project designed for trusted LAN environments. The MCP server does not implement authentication. Raw mode allows read/write access to any reachable Modbus device. Do not expose service ports to the public internet without additional security measures.
Three terminals, five minutes, zero soldering required.
git clone https://github.com/KerberosClaw/kc_modbus_mcp.git
cd kc_modbus_mcp
uv syncuv run python simulator.py
# Modbus TCP simulator running on port 5020# In another terminal
uv run python server.py
# MCP server running on port 8765, loaded devices.yamlnpm install -g mcporter
mcporter config add modbus --url http://localhost:8765/mcp
mcporter call modbus.list_devices
mcporter call modbus.read_device device=factory_sensor register=temperature
mcporter call modbus.write_device device=factory_sensor register=motor_speed value=1500
mcporter call modbus.device_status device=factory_sensorFor the "I don't want to open three terminals" crowd (understandable):
docker compose up -d
# Simulator on :5020, MCP server on :8765This is where the magic happens. Well, "magic" is generous -- it's just YAML. But it beats memorizing hex addresses. Define your Modbus devices in devices.yaml:
devices:
factory_sensor:
host: 192.168.1.100
port: 502
slave_id: 1
byte_order: big # big | little | mixed
registers:
temperature:
address: 0
function_code: 3 # 3=holding, 4=input
data_type: float32 # uint16, int16, uint32, int32, float32, bool
scale: 0.1
unit: "°C"
access: read
description: "Ambient temperature sensor"
motor_speed:
address: 4
function_code: 3
data_type: uint16
unit: "RPM"
access: read_write
description: "Motor speed setpoint"
pump_on:
address: 0
function_code: 1 # 1=coil
data_type: bool
access: read_write
description: "Pump on/off switch"| Type | Registers | Range |
|---|---|---|
bool |
coil (1 bit) | true/false |
uint16 |
1 | 0 – 65535 |
int16 |
1 | -32768 – 32767 |
uint32 |
2 | 0 – 4294967295 |
int32 |
2 | -2147483648 – 2147483647 |
float32 |
2 | IEEE 754 |
| Code | Name | Access |
|---|---|---|
| 1 | Read Coils | read |
| 2 | Read Discrete Inputs | read |
| 3 | Read Holding Registers | read/write |
| 4 | Read Input Registers | read |
The user-friendly stuff. The reason this project exists.
| Tool | Description |
|---|---|
list_devices |
List all configured devices |
list_registers |
List all registers of a device with metadata |
read_device |
Read a named register -- returns converted value + unit |
write_device |
Write a value to a named register |
device_status |
Check if a device is online |
For when you need to bypass all that nice abstraction and talk to registers like it's a bare metal Tuesday.
| Tool | Description |
|---|---|
read_registers |
Raw read by host/port/slave_id/fc/address |
write_registers |
Raw write by host/port/slave_id/fc/address |
scan_registers |
Scan address range for non-zero values |
A pymodbus-based Modbus TCP server that pretends to be a factory. The data is fake but the protocol is real. No hardware needed -- your laptop is the factory now.
| Register | Address | FC | Type | Behavior |
|---|---|---|---|---|
| temperature | HR 0-1 | 3 | float32 | Sine wave 20~30°C |
| humidity | HR 2-3 | 3 | float32 | Random 40~60%RH |
| motor_speed | HR 4 | 3 | uint16 | Holds written value |
| pressure | IR 0 | 4 | uint16 | Random 900~1100 kPa |
| pump_on | Coil 0 | 1 | bool | Holds written value |
| valve_open | Coil 1 | 1 | bool | Holds written value |
kc_modbus_mcp/
├── server.py # MCP Server entry point
├── simulator.py # Built-in Modbus TCP simulator
├── devices.yaml # Example device profile
├── src/
│ ├── profile.py # YAML profile loader + register resolver
│ ├── client.py # pymodbus async client wrapper
│ ├── converter.py # Data type conversion (raw ↔ engineering value)
│ └── tools.py # MCP tool definitions
├── openclaw-skill/ # OpenClaw skill wrapper
├── tests/ # Automated tests
├── docker-compose.yml
├── Dockerfile
├── pyproject.toml
├── DESIGN.md # Design document (Chinese)
├── .env.example
└── LICENSE
Sensible defaults included, because nobody should have to configure things just to see if they work.
| Variable | Default | Description |
|---|---|---|
MODBUS_PROFILE |
devices.yaml |
Path to device profile YAML |
MCP_HOST |
0.0.0.0 |
MCP server bind address |
MCP_PORT |
8765 |
MCP server port |
SIMULATOR_HOST |
0.0.0.0 |
Simulator bind address |
SIMULATOR_PORT |
5020 |
Simulator port |
For OpenClaw / local LLM agents, a wrapper script turns verbose MCP calls into something you can actually type without getting carpal tunnel:
modbus list
modbus status factory_sensor
modbus read factory_sensor temperature
modbus write factory_sensor motor_speed 1500See openclaw-skill/SKILL.md for details.
Things I will definitely get to. Eventually. Probably.
- Multi-device connection pooling
- Polling mode with configurable cache interval
- Change detection (notify on value changes)
- Modbus RTU (Serial) support
- Web UI for device profile editing